1.The experimental mode selection, in strict accordance with different Abel closed cup (Abel closed cup) standard operating procedures for flash point detection test, detected sample flash point value:
A.ISO13736, ISO1516, ISO1523 and other test mode selection.
B.Expected flash point search mode: Perform a quick test on the sample that does not know the expected flash point value, and retrieve the expected flash point.
C.User-defined, test parameters can be set according to different test requirements, convenient for users to research and development and simulation test operation. (Different standards of temperature control and ignition detection mode requirements are different, users can set the test mode)
2.Use Japan Mitsubishi original imported PLC programmable control unit, to achieve industrial precision standards. Large built-in storage capacity, convenient for future software upgrade and replacement. Reduce maintenance costs without additional software replacement costs.
3.The main parts of the instrument (PT100 temperature sensor, CRC thermocouple detector, ring heating wire, liquid crystal display, stirring motor, etc.) are imported from original brands to ensure the operating performance of the instrument to improve the loss of life.
4.High degree of automation: according to the operation mode on the LCD screen set the flash point test parameters, press the START key, the whole test process is automatically carried out. The screen directly displays the test temperature, curve, atmospheric pressure, detection times, heating rate and other data information.
6.The instrument can be extended to connect the independent test unit, and can be tested at the same time. A single instrument can be extended to simultaneously test the same or different open or closed flash points. (XF-2S/XF-4S multi-cup flash point) The main electrical parts of the control part and the measurement part are imported parts to ensure the reliability and stability of the instrument.
7.Self-fault diagnosis and alarm function.
8.Equipped with a standard needle printer, which can list the test results one by one.