1. Refrigeration system, simultaneous detection of 3 samples;
2.One-click automatic detection,eliminate human errors;
3.PID precise temperature control;
4. Record and playback the experiment process, no-missing every detail.
Automatic grease melting point meter can quickly and accurately determine the melting point of various block and paste samples.3 samples measured simultaneously. Through the digital optical sensor,the whole experiment process is digitized and transmitted to the computer, the intelligent software can automatically judge the melting point of oil, eliminate the subjective error of judging the melting point, and reduce the labor intensity of the experimenter. The instrument has its own heating system, which can ensure a stable heating rate. The platinum temperature sensor has the advantages of fast response and high accuracy compared with the traditional method of using mercury thermometer.
Inquire Now
1. Refrigeration system, simultaneous detection of 3 samples;
2.One-click automatic detection,eliminate human errors;
3.PID precise temperature control;
4. Record and playback the experiment process, no-missing every detail.
Model | INOY30 | INOY50 | INOY80 | INOY90 |
Temperature display range | 0-350℃ | 0-100℃ | 0-400℃ | 0-100℃ |
Temperature control range | RT-350℃ | (RT -20)-100℃ | RT-400℃ | (RT -20)-100℃ |
Temperature resolution | 0.1℃ | 0.1℃ | 0.1℃ | 0.1℃ |
Heating gradient | 0.1℃-20℃/ minutes | 0.1℃-10℃/ minutes | 0.1℃-20℃/ minutes | 0.1℃-10℃/ minutes |
Cooling rate | Wind cooling | Semiconductor cooling | Wind cooling | Semiconductor cooling |
Temperature accuracy | ±0.3℃ (<100℃) ±0.5℃ (>100℃) | ±0.3℃ (<100℃)
| ±0.2℃ (<100℃) ±0.4℃ (>100℃) | ±0.2℃ (<100℃)
|
Repeatability | Melting point repeatability was ±0.1℃ at 0.1℃/Min | Melting point repeatability was ±0.1℃ at 0.1℃/Min | Melting point repeatability was ±0.1℃ at 0.1℃/Min | Melting point repeatability was ±0.1℃ at 0.1℃/Min |
Detection method | Semi-automatic | Semi-automatic | Fully automatic (compatible with manual) | Fully automatic (compatible with manual) |
Video function | Photo | Photo and video | Photo and video | Photo and video |
Data preservation | 200 | 400 | 600 | 1000 |
Storage | 16G | 32G | 16G | 32G |
Display method | TFT high-definition true color screen | TFT high-definition true color screen | TFT high-definition true color screen | TFT high-definition true color screen |
Computer interface | USB RS232 network port | USB RS232 network port | USB RS232 network port | USB RS232 network port |
Capillary can be used | OD:1.3mm ID:1.1mm Length:100mm (Single and double opening)
OD:4.0mm ID:3.8mm Length:800mm (Large capillary)
| OD:1.3mm ID:1.1mm Length:100mm (Single and double opening)
OD:4.0mm ID:3.8mm Length:800mm (Large capillary)
| OD:1.3mm ID:1.1mm Length:100mm (Single and double opening)
OD:4.0mm ID:3.8mm Length:800mm (Large capillary)
| OD:1.3mm ID:1.1mm Length:100mm (Single and double opening)
OD:4.0mm ID:3.8mm Length:800mm (Large capillary)
|
Processing capacity | 3 pcs per batch | 3 pcs per batch | 3 pcs per batch | 3 pcs per batch |
Number of user management | - | 8 | 10 | 200 |
Video playback | - | YES | YES | YES |
User Management | - | YES | YES | YES |
Power supply | AC 220V 50/60Hz 120W | AC 220V 50/60Hz 120W | AC 220V 50/60Hz 120W | AC 220V 50/60Hz 120W |
Instrument size | 400*280*330mm | 400*280*330mm | 400*280*330mm | 400*280*330mm |
weight | 4.1kg | 4.1kg | 4.1kg | 4.1kg |