IAA6810 Atomic Absorption Spectrophotometer

IAA6810
IAA6810

IAA6810 Atomic Absorption Spectrophotometer

IAA6810 atomic absorption spectrophotometer is practical, miniaturized, intelligent, highly sensitive, stable, easy and safe to operate, and can meet the routine analysis needs of metal elements in biomedicine, environment, cosmetics, geology and other industries.

FEATURES

Innovative graphite furnace visualization system

The graphite furnace visualization system can visually monitor the dynamic evolution of the sample during the drying, ashing, and burning processes inside the graphite tube, and conveniently observe the optimal position and depth of the capillary needle of the autosampler entering the graphite tube,and the position of the platform inserted in the graphite tube to ensure the analysis accuracy and the life of the graphite tube.

The CCD camera installed in the instrument cooperates with the video capture software to monitor the inside of the graphite furnace in real time. The capillary injection needle and platform can be clearly displayed, which facilitates the operation of analysts and ensures high reliability of analysis.


Safe and Guaranteed

● The flame sensor identifies the flame by sampling the flame temperature, eliminating interference from external light on the sensor, and improving the reliability of flame identification.

● Automatic ignition is completed under computer control, ensuring that ignition can only occur when safety is met.

● When the flame extinguishes abnormally, it will automatically alarm and cut off the gas.

● The gas pressure sensor automatically alarms when the gas pressure is insufficient.

● The burner is inserted into the interlocking device to ensure safe operation.

● The power supply is cut off and the gas is cut off automatically.


Stable and Reliable

● Gas stability

The computer is used to control the gas flow. Due to the electronic flow controller, the gas output is more stable and the flow resolution is higher.

The function of storing the flow ratio of the best combustion aid and gas, which greatly simplifies the adjustment of the flow rate during each flame operation, and ensures the high sensitivity and good emphasis of the flame method.

● Optical stability

The optical system of the whole instrument is sealed in a shield to isolate it from the environment of the laboratory and maintain the stability of the optical path.

With the design of the integrated suspension shock absorber optical platform, the anti-seismic capacity of the optical system is enhanced, and the influence of mechanical deformation caused by temperature change on the optical system is reduced, even if the optical signal is used for a long time.

● Graphite furnace stability

Stable and reliable graphite furnace atomization, using PID technology, temperature control is more accurate.


Software Design

● Power-on self-detect, automatically detect communication, wavelength, slit and lamp position, etc.

● Automatically convert wavelength, slit size, lamp position, etc.

● Flame gas and combustion aid ratio control.

● Graphite furnace temperature program control, automatic dilution, automatic configuration curve, etc.

● Sample editing and measurement.

● Data processing and storage.

● Save quality control charts for all different statistical methods.

● Various treatment methods and corresponding methods for exceeding the standard concentration.


SPECIFICATIONS

Optical systemWavelength range190-900nm
MonochromatorC-T type of eliminating aberration monochromator
grating number1800lines/mm
Spectral bandwidth0.10.20.40.71.02.0 (6 levels automatic switching)
Wavelength accuracy±0.2nm
Wavelength repeatability±0.1nm
ResolutionThe spectral bandwidth can separate manganese double lines (279.5nm and 279.8nm) at 0.2nm.
Static baseline drift0.002ABS/30min (Cu)
Background correction systemTwo background subtraction methods, self-absorption and deuterium lamp, can correct 1A background
Element lamp6 lamps can auto-switch
Atomization SystemFlame analysisPrecisionRSD≤0.5%
Concentration (Cu)0.025μg/mL/1%
LOQ (Cu)0.004μg/mL
SprayerHigh efficiency glass sprayer
Graphite furnace analysisPrecisionRSD≤3%
Characteristic statistic (Cd)1.0×10-12g
LOQ (Cd)2.0×10-12g
Heating rate2000℃/sec
Heating range3000℃
Safety protectionGraphite furnace visual system, graphite furnace accidentally broken immediately stop heating and prompt alarm
Function expansionOptional hydride generator for atomic absorption analysis
Sample injection systemAutomatic samplerSample quantity85
Cup materialPolypropylene
Number of matrix modifier5
Standard cup volume2mL sample10mL reagent
Injection volume1μL-50μL
Injection accuracyWhen the volume is ≥10μL, better than 1%
Minimum increment1μL
Graphite furnace power supplyVoltage220V±22V
Power5000W
Dimension280mm×550mm×450mm
Main host power supplyVoltage220V±22V
Power200W
Dimension700mm×550mm×530mm